Half-Joint Design
Designs concrete half-joint (dapped-end) connections with the strut-and-tie method and checks them against ACI 318.
Checks the embedment depth of a steel balustrade post cast into a concrete slab edge, for bearing and edge shear-out to BS 8110-1.
Enter the post section (SHS or CHS pipe), embedment depth, rail height, panel width, line and point loads, and the distance from the post to the slab edge. The spreadsheet works out the factored load and moment on each post at the top of the concrete.
The post is treated as rigid in the concrete, with a linear bearing pressure that changes sign at depth y0. The spreadsheet solves for the two pressure blocks, confirms horizontal and moment equilibrium, and checks the peak bearing stress against 0.4 fcu.
Edge shear-out is checked at the face of the post against the maximum shear stress of BS 8110-1 clause 3.4.5.2, and at 1.5d against the design concrete shear stress vc of Table 3.8. It also gives the reinforcement area needed across the shear plane.
A summary line states whether the embedment depth is adequate and gives the maximum utilisation.
Questions before you buy, or trouble installing? Contact support.
Designs concrete half-joint (dapped-end) connections with the strut-and-tie method and checks them against ACI 318.
Designs a pile cap on a single pile, with or without construction eccentricity, to Eurocode 2.
Calculates the standard fire resistance R of rectangular and circular reinforced concrete columns to EN 1992-1-2.